MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Need to perform testing of emergency generator power operation and fire service. Re-inspection required
|
10/1/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Need to perform emergency generator power operation testing, fire service testing. Re-inspection required
|
9/30/2023
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Hoist ropes are rouged and have sufficient breaks to warrant replacement, need to replace within 90 days. Re-inspection required
|
9/30/2023
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Hoist ropes are rouged and have sufficient breaks to warrant replacement, need to replace ropes within 90 days. Re-inspection required
|
10/22/2024
|
A17.1-2016 : Elevators
|
3.27 - Crosshead Data Plate and Rope Data Tags
|
2.20.2
|
|
|
Replace missing crosshead data plate and hoist rope tag
|
11/5/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.11 Periodic Inspection and Test.
|
x
|
|
Incomplete inspection - test standby power and fire service.
|
11/21/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.28 - Terminal stopping devices
|
8.11.2.1.2(z)
|
x
|
x
|
Down normal limit switch not working, repair and reinspect. Did not red tag unit.
|
11/21/2020
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
This elevator has a backup emergency generator power that is used in case of a power outage. This system was setup and scheduled to be tested on 10/26/24, however the hospital staff failed to initiate the emergency generator test. Reinspection is required.
|
10/30/2024
|