Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A18.1-2005 : Lifts & Chairlifts 2.13 - Code Data Plate 2.13 x 1) A data plate shall be provided that indicates the A18.1 Standard to be used for inspections and tests. The data plate shall be in plain view, securely attached on the main line disconnect or on the controller. There is no code data plate showing A 18.1 2005, which is the code we are currently under. Ref: 2.13 3/4/2021
ASME A18.1-2005 : Lifts & Chairlifts 2.10 - Operating Devices and Control Equipment 2.10.6 Emergency Stop Switch x x 1) Platform lift is unsafe possible entrapment can happen. During my inspection of unit while testing the stop switch / alarm the unit would not run again. Ref: 10.2.2(a)(1) 5/23/2022
ASME A18.1-2005 : Lifts & Chairlifts 11 CSR 40-5.090 Inspection and Testing 10 Routine, Periodic, and Acceptance inspections andTest x 2) All tests shall be made in accordance with the applicable ASME code. Testing not completed. Re-inspect 5/23/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Telephone does not work