Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A18.1-2005 : Lifts & Chairlifts CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate The State Operating Certificate was not issued because of existing Violation which has now been corrected. 8/16/2023
ASME A18.1-2005 : Lifts & Chairlifts 2.1 - Runways 2.1.1 x Sheetrock in runway enclosure needs tape and mud on seams for fire rating 6/21/2021
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 (Re-Inspect) x Emergency light and bell not working 10/24/2022
ASME A18.1-2005 : Lifts & Chairlifts 2.11 - Emergency Signals 2.11.1 x The stop switch works and illuminates but doesn't have alarm bell when activated 8/16/2023