ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
|
|
5.2.1.1 not solid or fire proof
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.4 - Machine space
|
2.1.3.3
|
|
|
5.2.1.7.1. not solid or fire proof
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.4 - Hoistway door locking devices
|
2.12
|
x
|
|
5.2.1.12. runs with doors open, contacts at each floor no wired right
|
10/1/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.2 - Hoistway doors
|
2.12.7
|
x
|
x
|
2.5.7.5.1. more than 5 inches between hoist door and car gate when door is closed
|
10/1/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.1 - Car platform guard
|
2.15.9
|
|
|
5.2.1.15.2. no platform guard
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.3 - Final and emergency terminal stopping devices
|
2.25.3
|
x
|
x
|
5.2.2.13. top final
|
10/1/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
x
|
phone not working, no emergency light/bell
|
10/1/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing
|
2.4
|
x
|
x
|
5.2.1.4.4. low clearance
|
10/1/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
2.4.2
|
x
|
|
5.2.1.4.2. no protection
|
10/1/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
|
|
not self closing or locking
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
2.8
|
|
|
5.2.1.12. Hoistway wiring not in conduit or protected. Car light not on single circuit
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.34 - Flexible Hydraulic Hose and Fitting Assemblies
|
8.11.3.1.2 (q)
|
|
|
Rubber hose out of date
|
|