ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.2 - Hoistway doors 2.12.7 x x 2.5.7.5.1. more than 5 inches between hoist door and car gate when door is closed 10/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.10 - Hoistway construction 2.1 5.2.1.1 not solid or fire proof
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.4 - Hoistway door locking devices 2.12 x 5.2.1.12. runs with doors open, contacts at each floor no wired right 10/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.12 - Pipes, wiring, and ducts 2.8 5.2.1.12. Hoistway wiring not in conduit or protected. Car light not on single circuit
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.1 - Car platform guard 2.15.9 5.2.1.15.2. no platform guard
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 2.4.2 x 5.2.1.4.2. no protection 10/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.4 x x 5.2.1.4.4. low clearance 10/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.4 - Machine space 2.1.3.3 5.2.1.7.1. not solid or fire proof
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.3 - Final and emergency terminal stopping devices 2.25.3 x x 5.2.2.13. top final 10/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 not self closing or locking
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x x phone not working, no emergency light/bell 10/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.34 - Flexible Hydraulic Hose and Fitting Assemblies 8.11.3.1.2 (q) Rubber hose out of date