Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.1 - General fire protection 6.1.1 x All truss walls shall be properly enclosed. 4/30/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 6.1.3.3.5 x Skirt indexing test shall be performed. 4/30/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.2 Handrail must have 4" minimum vertical clearance from adjacent surfaces. 5/15/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.4 - Entrance and egress ends 6.1.3.6 x Entrance floors shall be finished. 4/30/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.6 - Caution Signs Fig. 6.1.6.9.1 x Rider caution signs shall be installed. 4/30/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 6.1.6.3.13 x A comb impact device test shall be performed. 10/7/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.8 - Deck barricades and antislide devices 8.11.4.1(h) 6.1.3.3.13 - Unit shall have deck barricades at top and bottom between adjacent unit. 5/15/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 6.1.6.7 x Demarcation lights shall be operational. 4/30/2020