Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)2 x The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. 3/11/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2 On-Site Documentation All the on site documentation required shall be provided in the machine room. An MCP shall be provided and kept in the machine room. 3/11/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Customer shall apply for a variance from the State of Missouri to allow this equipment to remain. This installation is a residential elevator operating in a commercial setting, as as such shall also comply with the following as it relates to amended sections of A17.1-2016 code per MO AHJ Memorandum 15-1. 3/11/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x 5.3.1.7.2 - The clearance between the face of the hoistway doors and the hoistway edge of the landing sill shall not exceed .75 inches. 3/11/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x x The distance between the hoistway face of the landing door or gate and the car door or gate shall not exceed 4 inches. If hoistway doors are found without door spacers or exceed this clearance the elevator is to be red tagged and not allowed to operate until corrected. The top of the door spacer shall be no less than 30 inches from the landing with a beveled top at a 75 degree angle. Elevator Red Tagged. 3/11/2024