Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.10 - Hoistway construction 2.1 Install and seal sheetrock inside the hoistway at the intermediate landing next to the entrance frame and above door header to provide fire restrictive construction of hoistway, and eliminate the recess. 10/16/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room access door needs to be self-locking and non-defeatable 11/1/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room access door shall be self-locking and non-defeatable 1/1/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 REPLACE DOOR LOCK WITH A NON DEFEATABLE TYPE 10/30/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed 1/1/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.11.1 Test and log firefighter operation monthly. 10/16/2021