Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone has to be installed in elevator cab. Re-inspection required 3/25/2024
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room door is required to be self closing & self locking 6/25/2024
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 2.26.4.1 All electrical equipment and wiring shall conform with NFPA70. Disconnect wiring shall be put in EMT pipe or greenfield less than 6 ft 6/25/2024
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.7.2 Clearance Between Hoistway Doors and Landing Sills x Clearance between the face of the hoistway doors and hoistway edge of the landing sill shall not exceed 9 mm for sliding doors 3/25/2024
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.8.3 Clearance Between Hoistway Doors and Car Doors or Gates x x The distance between the hoistway face of the landing door or gate and the car door or gate shall not exceed 100 mm 3/25/2024
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.18.3 Key-Operated Switches Hall buttons shall be operated by means of a key switch with the key removable only when switch is in the off position. Keyed switched shall not be of continuous pressure spring return type. 6/25/2024
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.7.1 Hoistway Enclosure Provided Where requires, landing openings shall be protected by swinging or sliding doors or gates. 1st floor door needs to be replaced. 6/25/2024
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.8.2 Car Doors and Gates A car door or gate will guard the opening to the height of at least 66 inches shall be provided at each entrance to the car 6/25/2024