Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.17 - Standby power operation 8.10.2.2.1(q) x Provide testing of emergency power operation with 125% of rated loaad. 11/20/2020
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.1 Emergency communications and alarm not functioning (Red Tag) x Provide means for two way conversation inside elevator. Phone is inoperative. 11/20/2020
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability x Provide means to verify telephone operability. Elevator phone line monitoring equipment has not been installed. 11/20/2020
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.10.2.2.2(l) x Provide type ABC fire extinguisher in close proximity to machine space. 11/20/2020
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 x Seal penetrations in hoistway wall. 11/20/2020
A17.1-2016 : Elevators 3.12 - Pipes, wiring, and ducts 2.8 x Electrical wire in hoistway needs to be in metal conduit. Incoming telephone line, and signal for emergency power are exposed. 11/20/2020
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.9 Elevator Corridor Call Station Pictograph x Post corridor call station pictograph next to top landing call station. "In case of fire do not use elevator" 11/20/2020
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device x x Provide testing of phase 1 operation by initiating devices. 11/20/2020
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.8 Switch Keys x Provide access to firefighter operation key on site for firefighters and emergency personnel. 11/20/2020