A17.1-2016 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
x
|
|
Seal penetrations in hoistway wall.
|
11/20/2020
|
A17.1-2016 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
2.8
|
x
|
|
Electrical wire in hoistway needs to be in metal conduit. Incoming telephone line, and signal for emergency power are exposed.
|
11/20/2020
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.1 Emergency communications and alarm not functioning (Red Tag)
|
x
|
|
Provide means for two way conversation inside elevator. Phone is inoperative.
|
11/20/2020
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.6 Verification of Telephone Operability
|
x
|
|
Provide means to verify telephone operability. Elevator phone line monitoring equipment has not been installed.
|
11/20/2020
|
A17.1-2016 : Elevators
|
2.7 - Fire Extinguisher
|
8.10.2.2.2(l)
|
x
|
|
Provide type ABC fire extinguisher in close proximity to machine space.
|
11/20/2020
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.10.2.2.1(q)
|
x
|
|
Provide testing of emergency power operation with 125% of rated loaad.
|
11/20/2020
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.9 Elevator Corridor Call Station Pictograph
|
x
|
|
Post corridor call station pictograph next to top landing call station. "In case of fire do not use elevator"
|
11/20/2020
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3.2 Phase I Operation Recall by Initiating Device
|
x
|
x
|
Provide testing of phase 1 operation by initiating devices.
|
11/20/2020
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.8 Switch Keys
|
x
|
|
Provide access to firefighter operation key on site for firefighters and emergency personnel.
|
11/20/2020
|