Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.10.2.2.5(a) Yes No Elevator pit electrical work has not been initiated. 9/6/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability Yes No Emergency Telephone system has not been established. 9/6/2022
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 Yes No Exposed wood & roof cap shall have fire rated material protection. 9/6/2022
A17.1-2016 : Elevators 3.13 - Windows, projections, recesses, and setbacks 2.1.6 Yes No Set backs in hoistway greater than 4 inches shall be beveled at an angle not less than 75 deg with the horizontal. 9/6/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device Yes Yes The Phase I Emergency Recall Operation by Fire Alarm Initiating Devices per 2.27.3.2.1(a)(b)(c). 9/6/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(b)(2) No No Provide on site documentation to include testing procedures. 6/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light not working. Bulbs? 6/5/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit No No CLEANING OF PIT NOT CHECKED AT THIS TIME 6/5/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No Independent keyswitch not working. Car still on auto 6/5/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No STILL NEEDS REPAIR OF INDEPENDENT SERVICE KEY SWITCH 6/5/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit No No Trash in pit. Sweep 6/5/2026