Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No The elevator enclosure shall be extended to the top of the cab. The area that passes the counterweight shall be solid material. 8/11/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No The car stop switch shall be operational. 8/11/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No Replace all broken slats on front & rear gates. 8/11/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No Provide a permanent pit stop switch adjacent to the pit door. 8/11/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes Yes The SOS is not operating. Elevator Red Tagged. 4/13/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes Yes Unit red tagged due to car being able to run with car gate and/or hoistway doors open. 4/11/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Entirety of the annual testing shall be completed. Testing stopped due to red tag. 4/11/2025
MO Minimum : Elevators (A) - Hoistways (A)16 No No Replace the missing interlock covers where needed.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Alarm bell shall work. 4/13/2023
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)4 No No The car top shall be completely covered and be able to support a 200 lbs. weight.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 No No A permanent capacity plate and a "No Passengers" sign shall be installed.
MO Minimum : Elevators (F) - Electrical Switches (F)2 Yes No The lower limit switches shall be raised up to the first floor if the lower landing is no longer in use. 8/11/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Alarm bell shall work. 6/26/2023
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No All means of access to elevator machine rooms shall be constructed and maintained in a clear and unobstructed manner. Need permanent stairs into machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No The machine room door shall be self-closing and self-locking.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No A permanent light fixture shall be installed in the pit with the switch adjacent to the bottom floor door.
MO Minimum : Elevators (I) - Pits (I)7 Yes No Install emergency stop switch in pit. 4/11/2025
MO Minimum : Elevators (I) - Pits (I)8 No No Provide a permanent, non-combustible pit sump pump cover.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Provide a code compliant MCP including onsite documents.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Yes No Second floor limit switch (floor selector switch) is not working in the UP direction. 4/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Yes No Second floor limit switch (floor selector switch) is not working in the UP direction. 6/26/2023