Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x Emergency light system not working 9/29/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Car top light fixture missing-exposed wires repair asap 10/29/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Oil leaking back through check valve-drop 1/2" in 10 min-closed machine room valve, o drop 10/29/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 10/29/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.5 Code Data Plate Provide a code data plate conforming to sec 8.9 8/30/2021
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x No emergency light/alarm 5/26/2020