A17.1-2016 : Elevators
|
4.8 - Hoistway enclosure
|
8.10.3.2.4(h)
|
x
|
|
Hoistway enclosures shall have flush surfaces on the hoistway side. Enclose or fill in around entrance jambs to meet fire codes at all entrances
|
9/24/2021
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.6 Verification of Telephone Operability
|
x
|
|
Emergency phone line monitoring shall be installed
|
9/24/2021
|
A17.1-2016 : Elevators
|
2.10 - Numbering of Elevators, Machines, Controllers, and Disconnect Switches
|
2.29.1
|
x
|
|
Mark car ID on 110v and main disconnects in electrical room
|
9/24/2021
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone line monitoring shall be installed. State issued 45 day extension
|
1/11/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6 General Maintenance Methods
|
x
|
|
Guide shoe on elevator car top is worn out and needs to be replaced. Re-inspection required
|