Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.10.2.2.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency Phone in car fails to establish two-way communication. No dial tone. 3.27 7/13/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers x Provide ABC Fire Extinguisher in Machine Space 8.6.1.6.5 7/13/2022
A17.1-2016 : Elevators 2.1 - Access to machine space 8.10.3.2.2(d) x Machine Room door needs to open farther to allow proper clearance access to the controller 3.7 7/13/2022
A17.1-2016 : Elevators 3.10 - Hoistway construction 8.7.2.1.1(b) x Hoistway needs to be fully enclosed with a two hour Fire rating. Remove wood decking at third floor landing behind fascia. 3.1 7/13/2022
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. 10/23/2024
MO Minimum : Elevators (H) - Machine Rooms (H)1 Means of access to machine space door shall be clear and unobstructed. Metal stands blocking door opening. 10/23/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) A code compliant MCP and all the on-site documentation required shall be provided in the machine room. 10/23/2024