Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-2016 : Elevators | 11.11 - Emergency Brake | 8.6.4.6.3 | x | E brake not working properly, adjust as needed. | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Provide missing bottom door (hoistway) fire retainer, all floors. | |||
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Provide testing of the battery backup system (R&R top of the hoistway). |