Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 3.27 - Crosshead Data Plate and Rope Data Tags 8.10.2.2.3(k) x Complete labeling of cartop data plate with permanent means. 5/18/2021
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.10.2.2.2(l) x Provide fire extinguisher within sight of machine space at top landing. 5/18/2021
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.10.2.2.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Provide means of two way communication for elevator car monitored 24 hrs a day. 5/18/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate no current cirt on site
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.4 x Provide pit ladder. 5/18/2021
A17.1-2016 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.10.2.3 Toe Board x Cartop railing clearance only 3" from hoistway. 5/18/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Fire service was not ready to be tested, installation of initiating devices is incomplete. 5/18/2021