Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.5 Code Data Plate Provide a code data plate conforming to sec 8.9 10/14/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Install cable guard on drive machine 104.1 6/20/2023
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)11 Hoist ropes need to shortened due to insufficient countrweight to buffer clearance with car level with top floor 5/27/2020
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)4 x x Excessive safety rope pull out on wind up safeties. 50" at time of testing/maximum is 36".Requires shortening of pull out. 8/27/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 10/14/2021