A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.10.2.2.5(a)
|
x
|
|
Provide and install an approved pit ladder.
|
8/5/2021
|
A17.1-2016 : Elevators
|
3.11 - Hoistway smoke control
|
8.10.2.2.3(q)
|
x
|
|
Install a heat detector and smoke detector at the top of the hoistway within 2 feet of the sprinkler head.
|
8/5/2021
|
A17.1-2016 : Elevators
|
1.5 - Car lighting and receptacles
|
8.10.2.2.1(e)
|
x
|
|
Provide 110 volt electricity to the car lighting , inside the car and on top of the car.
|
8/5/2021
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.4
|
x
|
x
|
Install a smoke detector in the controller cabinet. and test all fire system.
|
8/5/2021
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3
|
x
|
x
|
Fire caulk around the top of the hoistway and hall door 2nd. level.
|
8/5/2021
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.1 Emergency communications and alarm not functioning (Red Tag)
|
x
|
|
Provide a working emergency phone . The incoming line is dead, no dial tone.
|
8/5/2021
|