A17.1-2016 : Elevators
|
2.10 - Numbering of Elevators, Machines, Controllers, and Disconnect Switches
|
8.10.2.2.2(o)
|
x
|
|
Car top and controller shall have unit numbers.
|
2/9/2022
|
A17.1-2016 : Elevators
|
3.10 - Hoistway construction
|
8.7.2.1.1 Hoistway Enclosure Walls
|
x
|
|
Fire caulk around conduit in overhead and patch holes in front hoistway wall.
|
2/9/2022
|
A17.1-2016 : Elevators
|
3.17 - Door and gate equipment
|
8.10.2.2.3(w)
|
x
|
|
Install all pendant bolts on hoistway doors.
|
2/9/2022
|
A17.1-2016 : Elevators
|
3.20 - Governor rope
|
8.10.2.2.3(z)
|
x
|
|
Install a governor rope data tag.
|
2/9/2022
|
A17.1-2016 : Elevators
|
3.23 - Suspension Means
|
8.10.2.2.3(cc)
|
x
|
|
Install suspension means data tags.
|
2/9/2022
|
A17.1-2016 : Elevators
|
3.23 - Suspension Means
|
8.10.2.2.3(cc)
|
x
|
|
Install anti-spin device on suspension means.
|
2/9/2022
|
A17.1-2016 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
8.10.2.2.5(j)
|
x
|
x
|
Correct issue of safeties dragging on guide rails.
|
2/9/2022
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.11.1 Firefighters’ Emergency Operation Documentation
|
|
|
A record of findings for firefighters' service operation, tested monthly as required by 8.6.11.1 with identification of the person(s) that performed the operation, and the date shall be available on-site. The monthly fire service testing log is not being filled out monthly.
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3.2 Phase I Operation Recall by Initiating Device
|
x
|
x
|
Install firemans' return initiating devices near sprinkler heads that will cover elevator controller . Devices shall activate shunt trip.
|
2/9/2022
|