Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 3.10 - Hoistway construction 8.7.2.1.1 Hoistway Enclosure Walls x Fire caulk around conduit in overhead and patch holes in front hoistway wall. 2/9/2022
A17.1-2016 : Elevators 3.23 - Suspension Means 8.10.2.2.3(cc) x Install anti-spin device on suspension means. 2/9/2022
A17.1-2016 : Elevators 2.10 - Numbering of Elevators, Machines, Controllers, and Disconnect Switches 8.10.2.2.2(o) x Car top and controller shall have unit numbers. 2/9/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device x x Install firemans' return initiating devices near sprinkler heads that will cover elevator controller . Devices shall activate shunt trip. 2/9/2022
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.10.2.2.3(w) x Install all pendant bolts on hoistway doors. 2/9/2022
A17.1-2016 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 8.10.2.2.5(j) x x Correct issue of safeties dragging on guide rails. 2/9/2022
A17.1-2016 : Elevators 3.20 - Governor rope 8.10.2.2.3(z) x Install a governor rope data tag. 2/9/2022
A17.1-2016 : Elevators 3.23 - Suspension Means 8.10.2.2.3(cc) x Install suspension means data tags. 2/9/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation A record of findings for firefighters' service operation, tested monthly as required by 8.6.11.1 with identification of the person(s) that performed the operation, and the date shall be available on-site. The monthly fire service testing log is not being filled out monthly.