Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 x Call cancel button not working.
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.10.2.2.2(l) x MRL Traction unit with Control in 2nd landing Door jamb requires a Fire Extinguisher in the area of Controls. 2/16/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.6 Sump Pump Covers x Sump pump cover to be installed. 2/16/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device x x Remote location of Elevator Main Power & 110 Lighting Disconnects has a Sprinkler Head. Must add smoke detector & Heat device, 2/16/2022