A17.1-2016 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
x
|
|
Fire caulk around greenfield in hoistways, hall buttons & hall direction arrows
|
5/11/2022
|
A17.1-2016 : Elevators
|
4.8 - Hoistway enclosure
|
2.1.1
|
x
|
|
Remove wood from hoistway
|
5/11/2022
|
A17.1-2016 : Elevators
|
1.15 - sign and operating device symbols
|
8.10.2.2.1(o)
|
x
|
|
Braille car designation shall be posted at LL, P1 6th floors
|
5/11/2022
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3
|
x
|
x
|
FAID devices need to be tested
|
5/11/2022
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone inoperative. Re-inspection required
|
5/11/2022
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Video camera was not working. Operator could not view occupants in the elevator. The operator could not send a visible message. Voice communicator was working. Re-inspection required
|
|