Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair 3 way communication for proper operation 8/1/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability x Repair inoperative communication failure 8/1/2022
A17.1-2016 : Elevators 2.14 - Code data plate 8.9 x Code data tag shall be filled out with proper information 8/1/2022
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.7.9.1 x Provide 19ft candles illumination in the machine space (hoistway overhead) 8/1/2022
A17.1-2016 : Elevators 2.4 - Machine space 2.7.1 x Repair roof leaks by controller #2, by damper and over #2 disconnect 8/1/2022
A17.1-2016 : Elevators 3.19 - Guide rails fastening and equipment 2.23 x 2.23.7 Install missing bolt in fish plate on counterweight rail at top 8/1/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3 x x Program and test all heat and smoke detectors 8/1/2022