Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair 3 way communication for proper operation 8/2/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability x Repair inoperative communication failure 8/2/2022
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.4 x Control space shall have a self-closing self-locking door 8/2/2022
A17.1-2016 : Elevators 2.14 - Code data plate 8.9 x Code data tag shall be filled out with proper information 8/2/2022
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.7.9.1 x Provide 19ft candles at top floor for control station. 8/2/2022
A17.1-2016 : Elevators 2.4 - Machine space 2.1.3 x Seal all control-space penetrations 8/2/2022
A17.1-2016 : Elevators 2.4 - Machine space 2.7.1 x Repair roof leaks 8/2/2022
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 x Install an ABC fire extinguisher in the Control Space 8/2/2022
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 x Remove combustibles from back hoistway wall 8/2/2022
A17.1-2016 : Elevators 3.19 - Guide rails fastening and equipment 2.23 x 2.23.7 Install missing fish plate bolts on 2 top counterweight rails 8/2/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3 x x Program and test all heat and smoke detectors and test 8/2/2022