A17.1-2016 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
x
|
|
Remove combustibles from back hoistway wall
|
8/2/2022
|
A17.1-2016 : Elevators
|
2.4 - Machine space
|
2.1.3
|
x
|
|
Seal all control-space penetrations
|
8/2/2022
|
A17.1-2016 : Elevators
|
3.19 - Guide rails fastening and equipment
|
2.23
|
x
|
|
2.23.7 Install missing fish plate bolts on 2 top counterweight rails
|
8/2/2022
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Repair 3 way communication for proper operation
|
8/2/2022
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.6 Verification of Telephone Operability
|
x
|
|
Repair inoperative communication failure
|
8/2/2022
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3
|
x
|
x
|
Program and test all heat and smoke detectors and test
|
8/2/2022
|
A17.1-2016 : Elevators
|
2.4 - Machine space
|
2.7.1
|
x
|
|
Repair roof leaks
|
8/2/2022
|
A17.1-2016 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
x
|
|
Control space shall have a self-closing self-locking door
|
8/2/2022
|
A17.1-2016 : Elevators
|
2.3 - Lighting and receptacles
|
2.7.9.1
|
x
|
|
Provide 19ft candles at top floor for control station.
|
8/2/2022
|
A17.1-2016 : Elevators
|
2.7 - Fire Extinguisher
|
8.6.1.6.5
|
x
|
|
Install an ABC fire extinguisher in the Control Space
|
8/2/2022
|
A17.1-2016 : Elevators
|
2.14 - Code data plate
|
8.9
|
x
|
|
Code data tag shall be filled out with proper information
|
8/2/2022
|