Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.3 Pit has sprinkler so nema 4 conduit and boxes needed 4 ft and down. Existing from acceptance test
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone not working, alarm bell ok.
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.1 Emergency communications and alarm not functioning (Red Tag) x x Building phone line not ran for elevator 5/12/2022
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 x In case of fire don't use elevator signage needed 5/12/2022
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 x Sheetrock screws protruding into hoistway 5/12/2022
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Emergency battery operation couldn't be tested 5/12/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.8 x Liquid tight conduit needed in pit with sprinkler 5/12/2022