Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation A code compliant MCP and all the on-site documentation required shall be provided in the machine room. The logs are mostly blank. Need all documentation from 2022 & 2023.
A17.1-2016 : Elevators 3.22 - Wire rope fastening and hitch plate 2.20.9.7.2 Seizing of Rope Ends 2.20.9.7.2 - Suspension rope tail ends shall be properly seized/banded. They are currently wrapped in electrical tape.
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 2.7.6.3.4 x Remote governor set/rest does not work. Take corrective action as needed. 2/22/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability x Emergency communications loss monitor shall work. 2/22/2024