A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2 On-Site Documentation
|
|
|
A code compliant MCP and all the on-site documentation required shall be provided in the machine room. There is no MCP present. Need all documentation from 2022 & 2023.
|
|
A17.1-2016 : Elevators
|
3.22 - Wire rope fastening and hitch plate
|
2.20.9.5 Wedge Rope Sockets
|
|
|
2.20.9.5.4 - Hoist rope tail retaining clips shall be properly spaced.
|
|
A17.1-2016 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
|
|
Machine room door shall be self-closing and self-locking. The door jams before closed position.
|
|
A17.1-2016 : Elevators
|
2.43 - Emergency Brake, Ascending Car Overspeed, and Unintended Car Movement Protection
|
2.19.3
|
x
|
x
|
Rope gripper fails to drop with unintended motion. Elevator Red Tagged.
|
11/28/2023
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Two-way communication device shall work. The voice works, but video/text does not. Also, the agent gave the incorrect elevator number.
|
11/28/2023
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.6 Verification of Telephone Operability
|
x
|
|
Emergency communications loss monitor shall work
|
11/28/2023
|
A17.1-2016 : Elevators
|
1.2 - Stop Switches
|
2.26.2.5
|
x
|
|
Stop switch (push/pull style) shall be wired to alarm for audible notification.
|
11/28/2023
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Detector edge shall be bypassed on fire service.
|
11/28/2023
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Two-way communication device shall work. The voice works, but video/text does not. Also, the agent gave the incorrect elevator number.
|
2/22/2024
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.6 Verification of Telephone Operability
|
x
|
|
Emergency communications loss monitor shall work.
|
2/22/2024
|
A17.1-2016 : Elevators
|
1.2 - Stop Switches
|
2.26.2.5
|
x
|
|
Stop switch (push/pull style) shall be wired to alarm for audible notification.
|
2/22/2024
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.4.19.6
|
x
|
|
Detector edge shall be bypassed on fire service.
|
2/22/2024
|