Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.43 - Emergency Brake, Ascending Car Overspeed, and Unintended Car Movement Protection 2.19.3 x x Rope gripper fails to drop with unintended motion. Elevator Red Tagged. 11/28/2023
A17.1-2016 : Elevators 3.22 - Wire rope fastening and hitch plate 2.20.9.5 Wedge Rope Sockets 2.20.9.5.4 - Hoist rope tail retaining clips shall be properly spaced.
A17.1-2016 : Elevators 1.2 - Stop Switches 2.26.2.5 x Stop switch (push/pull style) shall be wired to alarm for audible notification. 11/28/2023
A17.1-2016 : Elevators 1.2 - Stop Switches 2.26.2.5 x Stop switch (push/pull style) shall be wired to alarm for audible notification. 2/22/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability x Emergency communications loss monitor shall work 11/28/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability x Emergency communications loss monitor shall work. 2/22/2024
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room door shall be self-closing and self-locking. The door jams before closed position.
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Detector edge shall be bypassed on fire service. 11/28/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation A code compliant MCP and all the on-site documentation required shall be provided in the machine room. There is no MCP present. Need all documentation from 2022 & 2023.
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Two-way communication device shall work. The voice works, but video/text does not. Also, the agent gave the incorrect elevator number. 11/28/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Two-way communication device shall work. The voice works, but video/text does not. Also, the agent gave the incorrect elevator number. 2/22/2024
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 x Detector edge shall be bypassed on fire service. 2/22/2024