Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency three way visual/testing communications was unable to be accessed by security personnel. Proper training may be needed to test/use the system. Re-inspection required 4/2/2026
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8 Yes No Label all disconnects in the machine room with feed source location 8/1/2022
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8 Yes No Provide a means to prevent the HVAC condensate from contacting the disconnects and controller 8/1/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Provide phone line for 3-way communication device and test 8/1/2022
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 Yes No Seal all hoistway penetrations 8/1/2022
A17.1-2016 : Elevators 2.4 - Machine space 2.7.1 Yes No Seal all machine room penetrations 8/1/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Three way visual communication was unable to be tested due to no training on the system. Proper training required and then shall be reinspected 11/27/2023