Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.3 2.8.3.3.2 Device when activated shall remove the power to the disconnect prior to the application of water 2/5/2024
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 Electrical wiring shall meet NFPA 70 Disconnects shall have sorce location labeled on them 2/5/2024
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 Disconnects per NFPA shall have 36in front and 30in side clear and unobstructed. Close hole in floor in front of the discinnect 2/5/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.11.1.3 Emergency Phone not workng Alarm Functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone calls out cannot make audio or visual contact. 12/18/2024
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.3 x Heat detector shall be installed not more than 24" from sprinkler head. Re-inspection required 10/4/2022
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.7.9.1 x Lighting in front of the controller, panel shall be of at least 19 fc and the pit shall have at least 10 fc at farthest point of light. Re-inspection required 10/4/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.3 x Sump pump needs to be wired for proper operation. Re-inspection required 10/4/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x No recall device tested, no one there to perform test. Video monitoring needs to be tested, no internet. Re-inspection required 10/4/2022
A17.1-2016 : Elevators 2.4 - Machine space 8.6.4.8 Machine Room and Machinery Space x Access and working space shall be provided and maintained about all electrical equipment to permit ready & safe operation and maintenance of such equipment 10/4/2022
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.5 x Pit illumination to be 10fc minimum 10/15/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 3.27.1 Phase I Emergency Recall Operation After Device Actuation x x Test all recall devices 10/15/2022