Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts 2.1 - Runways 2.1.1.7 The clearance between the platform and the rear wall shall be no less than 2" and no greater than 3". (Currently 1.5")
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts 2.1 - Runways 2.1.1.7 The clearance between the platform and the side wall shall be no less than 2" and no greater than 3". (Currently 5")
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts 2.1 - Runways 2.1.1.2 x The upper door clearance on the hoistway side shall be no greater than 3" from the sill. (Currently 3.75") 8/18/2023
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts 2.1 - Runways 2.1.1.3 x The lower door clearance on the hoistway side shall be no less than 3/8" and no greater than 3/4". (Currently 3 3/4") 8/18/2023
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts 2.1 - Runways 2.1.1.4 The hoistway door interlocks have an optical sensor for the electrical portion of the interlock and is not code compliant.
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts 2.11 - Emergency Signals 2.11.1 x x The emergency alarm bell does not work. Unit Red Tagged for multiple reasons. 8/18/2023