ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts
|
2.1 - Runways
|
2.1.1.7
|
|
|
The clearance between the platform and the rear wall shall be no less than 2" and no greater than 3". (Currently 1.5")
|
|
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts
|
2.1 - Runways
|
2.1.1.7
|
|
|
The clearance between the platform and the side wall shall be no less than 2" and no greater than 3". (Currently 5")
|
|
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts
|
2.11 - Emergency Signals
|
2.11.1
|
x
|
x
|
The emergency alarm bell does not work. Unit Red Tagged for multiple reasons.
|
8/18/2023
|
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts
|
2.1 - Runways
|
2.1.1.4
|
|
|
The hoistway door interlocks have an optical sensor for the electrical portion of the interlock and is not code compliant.
|
|
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts
|
2.1 - Runways
|
2.1.1.3
|
|
x
|
The lower door clearance on the hoistway side shall be no less than 3/8" and no greater than 3/4". (Currently 3 3/4")
|
8/18/2023
|
ASME A18.1-2014 : Platform Lifts & Stairway Chairlifts
|
2.1 - Runways
|
2.1.1.2
|
|
x
|
The upper door clearance on the hoistway side shall be no greater than 3" from the sill. (Currently 3.75")
|
8/18/2023
|