Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 x Item 2.1.6 Hoist way enclosure shall be smooth, remove exposed shaft liner screw tips. 10/5/2022
A17.1-2016 : Elevators 3.13 - Windows, projections, recesses, and setbacks 2.1.6 x Item 2.1.6.2(c) Beam pocket setbacks more than 4 inches shall be beveled not less than 75 deg from horizontal. 10/5/2022
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2 x 2.27.2.3 requires visual notification signal at main landing fixture. 10/5/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.9 Elevator Corridor Call Station Pictograph x Each Elevator landing shall have the signage In Case of Fire Elevators are Out of Service Use Stairs. 10/5/2022
A17.1-2016 : Elevators 2.1 - Access to machine space 3.7.1 x 2.7.3.4.1(a)(b)(c) Machine room door shall be self-closing & locking kept closed & locked. 10/5/2022
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 x Type ABC Fire Extinguisher shall be permanently mounted in the elevator machine room. 10/5/2022
A17.1-2016 : Elevators 2.4 - Machine space 8.6.4.8 Machine Room and Machinery Space Must not store none elevator equipment in the Machine Room. 8.6.4.8