Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.4 - Machine space 2.7.1.1 Machine Room Ceiling panels need to be replaced (2nd violation: 2019 and 2020) 4/27/2022
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal Resecure machine room smoke detector to ceiling (2nd violation: 2019 and 2020) 7/12/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)6 Detector edge shall work independent of cab lighting circuit (reinspection needed) 4/27/2022
MO Minimum : Elevators (I) - Pits (I)1 Pit Scavenger pump shall be removed. Reinspection needed 4/27/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Remove oil pads from pit and clean pit 4/27/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 MCP shall be kept in equipment room, including Testing Procedure and Fire service testing log, recorded monthly. 4/27/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.14 - Ventilation 2.14.3.3 Cab forced ventilation fan shall work 4/27/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.14 - Ventilation 2.14.2.3 Cab fan shall work (TKE quoted) 4/27/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.4 - Machine space 2.7.1.1 Machine Room Ceiling panels need to be replaced (2nd violation: 2019 and 2020) 9/10/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)6 Detector edge shall work independent of cab lighting circuit (reinspection needed) 9/10/2020
MO Minimum : Elevators (I) - Pits (I)1 Pit Scavenger pump shall be removed. Reinspection needed 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Remove oil pads from pit and clean pit 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 MCP shall be kept in equipment room, including Testing Procedure and Fire service testing log, recorded monthly. 9/10/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Machine Room shall have proper Fire Extinguisher, missing. 11/16/2022
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be kept clean and dry. Remove rust from pit equipment , repaint, investigate/repair water leak. 11/16/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. Provided by Elev Co 11/16/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. (Cert on display expired 2019) 11/16/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x 2-WAY COMMUNICATION DEVICE SHALL WORK. (Dials repeatedly, never connects 10/24/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting x Must make Emergency Light operable. 8.6.4.15 8/13/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make Emergency alarm operable. 8.6.4.15 8/13/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Alarm shall work with power loss. (Faulty button) 9/16/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Door Systems x Missing upthrust roller, 2nd floor door. 9/16/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x 2-WAY COMMUNICATION DEVICE SHALL WORK. (Dials repeatedly, never connects 10/24/2022
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Resecure machine room smoke detector to ceiling (2nd violation: 2019 and 2020) 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x telephone will not call out 7/29/2018