Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 No No Feeder location for the main and lighting branch circuits shall be marked on the disconnects. 8/12/2026
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 No No Feeder locations for the main and lighting branch circuits shall be marked on the disconnects.
A17.1-2016 : Elevators 3.2 - Car top light and outlet 8.11.2.1.3(b) No No Car top work light does not work
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) No No A record of firefighters service operation, tested monthly as required by 8.6.11.1, with identification of the person(s) that perfomed the operation and the date shall be avaliable on site. 8/12/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation No No A code compliant MCP and related on-site documentation shall be provided in the machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No A data plate, permanently and securely attached, shall be provided in the pit, in the vicinity of the Counterweight buffer indicating Maximum designed counterweight runby.
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.6.4.13 No No Adjust outer upthrust roller bearings for proper clearance to door hanger track
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No 2-WAY COMMUNICATION DEVICE SHALL WORK. Voice works, Camera works, text do not.