ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency Telephone did not have an active incoming line. Alarm Bell did work.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
x
|
|
ASME A17.1 Item 2.7.3.4.1 access door shall be self-closing and self-locking. Machine room door requires a closure.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.7 - Fire Extinguisher
|
8.6.1.6.5
|
|
|
Class ABC fire extinguisher in elevator electrical machine room.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.15 - sign and operating device symbols
|
8.6.1.6.7
|
|
|
8.6.1.6.7 Hoist way Door Jambs are missing Braille Symbols @ all landings.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.7 Firefighters' Emergency Operation: Operating Procedures
|
x
|
|
Item 2.27.7.1 Phase I Emergency Recall Instructions Operation Instruction missing @ Main Egress Landing where Key Switch is located.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.7 Firefighters' Emergency Operation: Operating Procedures
|
x
|
|
A17.1 Item 2.27.7.2 Fire Service Phase II Operation Instructions is missing from the Elevator Car Control Panel.
|
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.9 Elevator Corridor Call Station Pictograph
|
|
|
2.27.9 Elevator Corridor Call Station Pictorial In Case of Fire Do Not Use Elevator is missing at all landings.
|
|