MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
x
|
|
Maximum hoisting capacity needs to be listed on hoisting beam.
|
10/11/2024
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Vent needs to be more than 36" from heat & smoke detector at top landing.
|
10/11/2024
|
A17.1-2016 : Elevators
|
2.3 - Lighting and receptacles
|
2.7.9.1
|
x
|
|
There is not enough light in control space.
|
10/11/2024
|
A17.1-2016 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
2.8
|
x
|
|
Heat detector shall be within 24" of sprinkler head.
|
10/11/2024
|
A17.1-2016 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
x
|
|
Fire caulk holes, gaps under sills, & around all beams in hoistway.
|
10/11/2024
|
A17.1-2016 : Elevators
|
3.10 - Hoistway construction
|
2.1
|
x
|
|
Fill 6" gap at the top landing in hoistway and clean down hoistway.
|
10/11/2024
|
A17.1-2016 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
2.8
|
x
|
|
Relocate heat and smoke detectors from hoisting beam in hoistway to the ceiling of the hoistway.
|
10/11/2024
|
A17.1-2016 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
2.8
|
x
|
|
Plug holes in electrical boxes at the top of hoistway.
|
10/11/2024
|
A17.1-2016 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
2.8
|
x
|
|
Add GFCI outlet at top of hoistway.
|
10/11/2024
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.5
|
x
|
|
The pit light shall be operational.
|
10/11/2024
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.4
|
x
|
|
Pit ladder is 42" & needs to be 48" above the sill.
|
10/11/2024
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2.5 Sump Pump Required/Capacity (Re-Inspect)
|
x
|
|
The sump pump is not wired.
|
10/11/2024
|