Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements the wire from the relay on the upper right of the controller to the terminal block on the lower left needs to be ran behind the controller panel not in front of the open relays
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers the machine room fire extinguisher does not have a current inspection tag
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x replace the emergency light battery it is dead 10/11/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x the emergency lights did not come on 11/16/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x emergency lights did not come on, replace the emergency light battery 11/3/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Replace emergency light battery,it is dead 12/16/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Machine room fire extinguisher inspection tag is expired, have the fire extinguisher inspected and tagged
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace all pit equipment that is rusted and falling apart weakened metal structures no longer meet factor of safety minimums, see ladder and pit channels
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x x Emergency lights inoperative.
MO Minimum : Elevators (I) - Pits (I)2 replace pit channel that is rusted and galling apart, weakened metal pit channel no longer meets factor of safety minimums
MO Minimum : Elevators (I) - Pits (I)5 the bottom of the pit ladder is rusted and is falling apart, the only thing supporting weight on the ladder is the wall mounts
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Door reversal device that can be effected by smoke shall be disabled on fire service phase 1 recall 12/16/2024
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal The audible signal did not work on fire service recall
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal the fire service phase 1 recall audible signal did not work
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x door reopening devices that are sensitive to smoke or flame shall be rendered inoperative on fire service 11/3/2023
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service test and post test log in the machine room
MO Minimum : Elevators (S) - Fire Service (S)1 x x infrared door edge is to be disabled on fire service operation phase 1 and 2 11/16/2022
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal x the audible signal for fire service phase 1 recall did not work 11/16/2022
MO Minimum : Elevators (S) - Fire Service (S)1 x x on fire service phase 2 operation the doors open all the way even after the door open button is released 11/16/2022
MO Minimum : Elevators (S) - Fire Service (S)1 x x the stop switch is to be disabled on fire service phase 1 recall 11/16/2022
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) the infrared edge is to be disabled during fire service phase 1 and 2, it currently works during both phase 1 and 2 10/11/2021
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal the fire service audible signal did not work 10/11/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the certificate in the machine room is to be updated every year with the new copy
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room needs to be updated with the current operating certificate annually
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate in the machine room expired in 2017, update with current state operating certificate when received