Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No No active phone line or internet for video. 1/16/2025
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Yes No There is no fire extinguisher at machine space area on 4th floor. 1/16/2025
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 Yes No Fourth floor heat detector shall be more than 3' from HVAC venting. 1/16/2025
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 2.26.4.1 Yes No Shunt auxiliary contacts are not functional. 1/16/2025
A17.1-2016 : Elevators 3.12 - Pipes, wiring, and ducts 2.8 Yes No Pit sprinkler piping infringes on car, need to relocate. 1/16/2025
A17.1-2016 : Elevators 3.10 - Hoistway construction 2.1 Yes No Fill hoistway fire penetrations with approved material. 1/16/2025
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Yes No There is no fire extinguisher at machine space area on 4th floor. It shall be provided. 4/3/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 8.11.3.1.1(q) Yes No Elevators that are equipped to operate on Emergency Power shall be tested operating on Em Power, Annually.
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 8.11.2.1.2(p) No No Disconnects are obstructed by building supplies being stored in the Disconnect room. Must maintain at least 36" clearance and keep flammables out of all electrical rooms.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Testing incomplete: Only tested FAID and identified hoistway fire penetrations. Car sill hit pit sprinkler piping, crew attempted repairs. Testing stopped. All acceptance testing shall be completed. 1/16/2025