Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x This is a winding drum traction residential elevator in a commercial setting. A variance will need to be applied for with the state of Missouri for this unit to remain in a commercial setting. 12/4/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x This is a winding drum traction residential elevator in a commercial setting. A variance will need to be applied for with the state of Missouri for this unit to remain in a commercial setting.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x x Need door guards installed on all 3 hall/hoistway doors. Elevator Red Tagged. 12/4/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency communication shall be installed in the car. 12/4/2025
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. 11/21/2025