Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. x 8.6.5.8 - Possible single bottom jack. Installation year says 2002, but it appears this unit was an older unit that was modernized around 2002. Provide documentation to prove unit does not have a single bottom jack. 1/31/2025
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x All smoke and heat detectors shall be landed into the controller and checked from proper operation and function. 1/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records x An MCP is required on-site. 1/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Check the hoistway door closers for proper closing. 1/31/2025
MO Minimum : Elevators (H) - Machine Rooms (H)2 x Guard or gutter pipes conveying water over the pump unit. 1/31/2025
A17.1-1996 : Elevators 2.10 - Numbering of elevators, machines, and disconnect switches 211.9 x Hoistway doors shall be numbered. 1/31/2025
MO Minimum : Elevators (H) - Machine Rooms (H)2 x Machine room door shall be fire rated and shall be self-closing and self-locking. 1/31/2025
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Machine room smoke detector needs to be relocated to a code compliant location. 1/31/2025
MO Minimum : Elevators (H) - Machine Rooms (H)8 x Main line disconnect to be moved. Currently over the pump unit flush to the wall next to the controller. There is no working clearance. 1/31/2025
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) x Permanent code compliant lighting shall be provided in the machine room. 1/31/2025
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) x The pit light shall be operational and shall be guarded. 1/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection x There are leaky joints on hydraulic line. Take corrective action as needed. 1/31/2025
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)4 x There is no data tag on the controller or crosshead. 1/31/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x There is no phone line. 1/31/2025