ANSI/ASSP A10.4-2016 : Hoists
|
16.7 - Car Frame and Platform Connections
|
16.7
|
Yes
|
No
|
Hinges @25 needs more than 1 screw on frame side.
|
6/2/2026
|
|
ANSI/ASSP A10.4-2016 : Hoists
|
5.6 - Landings
|
5.6
|
Yes
|
No
|
Multiple Hoistway landing door sills need additional screws for proper support. (15th floor and above)
|
6/2/2026
|
|
ANSI/ASSP A10.4-2016 : Hoists
|
5.6 - Landings
|
5.6
|
Yes
|
No
|
Need to erect walls/barriers at 2nd landing to restrict contact of at least 30" from lift. (full height walls, standard strength)
|
6/2/2026
|
|
ANSI/ASSP A10.4-2016 : Hoists
|
5.6 - Landings
|
5.6
|
Yes
|
No
|
Cover landing windows to restrict contact of at least 30" from lift. To include restriction of opening windows. Affecting at least 4,7,10,14,17,20,23, and 27
|
6/2/2026
|
|
ANSI/ASSP A10.4-2016 : Hoists
|
5.1 - Tower or Mast Construction
|
5.1.1
|
Yes
|
No
|
Multiple bent/damaged cross-braces(lacing). Repair/replace to OEM spec.
|