A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.9 Elevator Corridor Call Station Pictograph
|
Yes
|
No
|
"In Case of Fire" signage shall be provided in hallway at each landing
|
|
|
A17.1-2016 : Elevators
|
4.12 - Standby power selection switch
|
2.27.2
|
Yes
|
No
|
Emergency Power / Standby power shall be tested
|
|
|
A17.1-2016 : Elevators
|
3.27 - Crosshead Data Plate and Rope Data Tags
|
2.20.2
|
Yes
|
No
|
Crosshead data plate shall be provided and engrave
|
|
|
A17.1-2016 : Elevators
|
2.6 - Ventilation
|
2.7.9.2
|
Yes
|
No
|
Air conditioning shall be installed and function to keep controllers at manufacturers recommended temperature.
|
|
|
A17.1-2016 : Elevators
|
2.5 - Housekeeping
|
8.6.4.8 Machine Room and Machinery Space
|
Yes
|
No
|
Machine room, car top, and pit need cleaned of construction dust, dirt, and debris
|
|
|
A17.1-2016 : Elevators
|
2.4 - Machine space
|
2.7.1
|
Yes
|
No
|
Machine room shall be 2 hour fire rated. Wood panels shall be removed.
|
|
|
A17.1-2016 : Elevators
|
2.3 - Lighting and receptacles
|
2.7.9.1
|
Yes
|
No
|
Machine room light switch shall be located at the point of entry
|
|
|
A17.1-2016 : Elevators
|
2.3 - Lighting and receptacles
|
2.8.2
|
Yes
|
No
|
Non-elevator related flex and electrical wiring shall be removed from the machine room.
|
|
|
A17.1-2016 : Elevators
|
2.1 - Access to machine space
|
2.7.1.1
|
Yes
|
No
|
Machine room stairs do not allow for proper path and clearance to controllers. Handrail presents cut hazards. Remove homemade stairs and replace with ladder or stairs that do not impede access to controller and disconnects.
|
|
|
A17.1-2016 : Elevators
|
2.1 - Access to machine space
|
2.7.1.1
|
Yes
|
No
|
Machine room floor has a large gap around the entire perimeter. Enclose floor to prevent trip hazard and prevent items from entering hoistway.
|
|
|
A17.1-2016 : Elevators
|
1.4 - Sills and car floor
|
2.11.11.1
|
Yes
|
No
|
Hall Sill to hall floor presents a trip hazard on floors 1, M, 2, 4, 5,6,7,8,9,10,11,12,13. Hall floor shall be level with hall sill.
|
|