MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)9
|
|
|
Remove existing machine room motor disconnect and replace with proper disconnect. NEC Code 620.51
|
1/5/2021
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)9
|
|
|
Mainline Disconnect to be replaced and moved to allow proper access
|
1/5/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams
|
|
|
No wiring diagrams (1926 Otis elevator)
|
1/5/2021
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
Provide proper access to roof to provide proper access to elevator machine room. 2.1- Rule 101.3b (1)
|
1/6/2021
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
Install Proper machine room door. 2.1 - 101.3c(2)
|
1/5/2021
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
Install proper machine room lighting. 2.3 -101.5a
|
1/5/2021
|
MO Minimum : Elevators
|
(K) - Car Platforms and Car Slings
|
(K)6
|
|
|
Has active Floating platform switch required to be made inactive. Code 210.12
|
1/5/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
No records
|
1/5/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
No DO NOT USE ELEVATOR IN CASE OF FIRE
|
1/5/2021
|