Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone does not operate. 7/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No maintenance control plan on site
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No hard copy maintenance records on site
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(c) On-Site Documentation (Written Checkout Procedures) Written checkout procedure for overspeed valve test needs to be kept in the machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Distance between swing hoistway door and edge of landing sill exceeds .75 inches at the bottom and third landings. A17.1 1996 rule 110.4 7/18/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(c) On-Site Documentation (Written Checkout Procedures) Written checkout procedure for overspeed valve needs to be kept in the machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.7.2 Periodic Test Record (Test Tags) Install periodic test tag for pressure relief test
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x x Distance between hoistway swing door and the edge of the landing sill exceeds .75 inches at all landings (second notice). A17.1 1996 rule 2500.11 12/4/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-closing
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-closing.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light does not illuminate.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Perform pressure relief test 7/18/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Perform safety test 7/18/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing Perform overspeed valve test on or before next inspection