MO Minimum : Elevators
|
(I) - Pits
|
(I)7
|
|
|
Pit needs stop switch
|
11/16/2025
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
Governor releasing carrier needs babbited rope. Using crosbies now. Works but wrong application.
|
11/16/2025
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
pit light has been added but not completed. Wiring in place but not hooked up yet to fixture
|
11/16/2025
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)5
|
|
|
pit needs access ladder installed
|
11/16/2025
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
The wind up safety pull out cable must be babbited on gov rope attachment assembly. Governor rope still babbited but pull out cable is crosbied to gov rope beside assembly.
|
|