Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)16 Exposed 110 volt wiring on door operator needs to be enclosed in metal raceway. 9/21/2022
MO Minimum : Elevators (A) - Hoistways (A)16 Install cover over exposed 110 volt wiring on car door control box. 9/21/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Insufficient car lighting inside the elevator. Car lighting needs to be a minimum of 5 foot candles of illumination. 9/21/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Elevator cab lighting is insufficient, less than 5 foot candles of illumination. 9/20/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x PHONE IS NOT WORKING
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Braille plates next to car button #1, and on floor 1 entrance frame, need to have a star on them to designate 1 as the main fire landing. Remove star on LL car button, and on floor LL entrance frame. 9/20/2022
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x REPLACE BAD HOIST ROPES
MO Minimum : Elevators (S) - Fire Service (S)1 x Door does not open when door open button is pushed while elevator is on fire service phase 2 operation. 9/16/2020
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Test and log firefighter operation monthly 9/21/2022
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Test and log firefighter operation monthly 9/20/2022
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Remove firefighter call cancel button from car operating panel. Firefighter operation on this elevator was not designed for call cancel feature. 8/31/2022
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter operating instructions inside the elevator that comply with fire service features that the elevator was constructed to meet. Existing signage is incorrect. 9/21/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current operating certificate inside machine room 9/21/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state operating certificate in machine room. 9/20/2022